What is CGA540 With Flowmeter Gauge High Pressure For Oxygen Cylinder?

CGA540 With Flowmeter Gauge High Pressure For Oxygen Cylinder is a high-pressure oxygen cylinder pressure reducer with a flow meter. It uses the CGA540 standard interface and is specifically designed for pressure reduction and flow regulation of medical or industrial oxygen cylinders. It reduces the high-pressure oxygen (usually 15-20 MPa) inside the steel cylinder to […]

What is CGA540 With Flowmeter Gauge High Pressure For Oxygen Cylinder? Read More »

How to Choose Oxygen Regulator for Medical Equipment for the African Market

Adapt to the characteristics of the African marketAir source type adaptationHigh pressure oxygen cylinder: It is still mainstream in areas with poor infrastructure, and a regulator with an inlet of 150-300 bar needs to be selected.Oxygen concentrator/concentrator: In cities and hospitals with relatively stable electricity, it can be equipped with a regulator with an inlet

How to Choose Oxygen Regulator for Medical Equipment for the African Market Read More »

What types of medical oxygen regulators are commonly used in the Zambian market?

1、 Classified by structure and working principle Single stage regulatorSimple structure, suitable for scenarios with minimal pressure fluctuations, such as small clinics, home oxygen therapy, etc. It is widely used in primary healthcare institutions and home care in Zambia.Double stage regulatorTwo stage pressure reduction, more stable output pressure, suitable for scenarios with large inlet pressure

What types of medical oxygen regulators are commonly used in the Zambian market? Read More »

What are the classifications of interfaces and adaptation systems for medical oxygen regulator?

The classification of interfaces and adaptation systems for different medical oxygen pressure reducers is directly related to the compatibility of the equipment with different gas sources or oxygen supply systems, and is a key element in ensuring safe and effective oxygen supply. 1、 Classified by interface type (connected to the gas source end) 1. Oxygen

What are the classifications of interfaces and adaptation systems for medical oxygen regulator? Read More »

How to choose manufacturer for medical oXYGEN REGULATOR?

The following are the steps and key points to pay attention to when choosing a medical pressure reducer manufacturer: 1. Qualifications and Certification Medical Device Registration Certificate: Import Medical Device Registration Certificate (for imported products). Production License: Manufacturers need to have a medical device production license to prove their production qualifications Quality Management System Certification:

How to choose manufacturer for medical oXYGEN REGULATOR? Read More »

How to choose medical regulator for oxygen cylinders?

It is necessary to ensure that the inlet connector of the pressure reducer matches perfectly with the valve interface of your oxygen cylinder.Common interface standards for medical oxygen cylinders:G5/8 “(common national/European standard): The standard interface for many medical oxygen cylinders in China and Europe.American standard thread: such as CGA 870 commonly used in the United

How to choose medical regulator for oxygen cylinders? Read More »

What is the difference in the use of CGA 580 and CGA 510 GAS CYLINDER reGULATOR?

CGA 580 and CGA 510 are two different cylinder fitting standards developed by the American Compressed Gas Association. Their core difference is that they are physically non interchangeable, aimed at preventing the wrong regulator from being mistakenly connected to the wrong cylinder, thereby avoiding serious safety accidents. CGA 580 (inert gases such as argon and

What is the difference in the use of CGA 580 and CGA 510 GAS CYLINDER reGULATOR? Read More »

What are the types of welding pressure reducers used in Turkmenistan?

The types of welding pressure reducers used in Turkmenistan are basically consistent with international standards, mainly including oxygen pressure reducers, acetylene pressure reducers, argon pressure reducers, carbon dioxide pressure reducers, etc. These pressure reducers can be divided into single-stage and two-stage types according to the maximum intake pressure. Among them, single-stage pressure reducers have a

What are the types of welding pressure reducers used in Turkmenistan? Read More »

What is the pressure range of welding pressure reducers used in Uzbekistan?

The pressure range of welding pressure reducers used in Uzbekistan is basically the same as that in Kazakhstan, following international standards. The input pressure is usually 15MPa (about 150bar), and the output pressure adjustment range varies depending on the gas type and purpose, generally ranging from 0.02-4MPa (0.2-40bar). The adjustment range of oxygen pressure reducers

What is the pressure range of welding pressure reducers used in Uzbekistan? Read More »

What is the pressure range of the welding regulator used in Kazakhstan?

The pressure range of welding pressure reducers used in Kazakhstan follows international standards, with an input pressure typically of 15MPa (about 150bar) and an output pressure adjustment range of 0.02-4MPa (0.2-40bar) depending on the type and purpose of the gas. The adjustment range of oxygen pressure reducers is usually 0.02-2MPa, acetylene pressure reducers are 0.01-0.15MPa,

What is the pressure range of the welding regulator used in Kazakhstan? Read More »