How to Choose Explosion-Proof Pressure Gauges, Match Pressure Ranges, and Install Them on Site — A DERKIA Practical Guide

In oil & gas, chemicals, gas filling stations and mines, a pressure gauge is not just something that shows a number.

Choose the wrong explosion-proof rating and you fail inspection. Choose the wrong range and the pointer shakes itself to death. Install it the wrong way and even an expensive gauge is wasted.

Here is how DERKIA, as a factory, breaks it down into three parts.

Part 1 — How to Choose an Explosion-Proof Pressure Gauge (5 Checks)

1. First: does it really need to be “explosion-proof”?

  • Pure mechanical gauge, no electrical contacts → not electrical explosion-proof; it is only a “safety type” (blow-out back, safety glass)
  • With electrical contacts, transmitter or switch output → must be a certified explosion-proof gauge
In short: if there is electricity inside and a spark is possible, it must carry an Ex certificate to enter a hazardous area.

2. Choose the protection type (Ex d / Ex i)

 
Type
Principle
Suitable zone
Typical application
Ex d flameproof
Enclosure contains internal explosion, flame cannot escape
Zone 1 / Zone 2
Wellhead, manifold, pump discharge, compressor
Ex ia intrinsically safe
Limits energy; no ignition in normal or fault condition
Zone 0 / 1 / 2
Tank top, sealed cabin, hydrogen station, control loop
Ex tD dust-proof
Prevents ignition of combustible dust
Zone 20/21/22
Coal dust, flour, powder workshops

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

  • Natural gas / propane (IIA) → Ex d IIA T4 is sufficient
  • Ethylene / mixed petrochemical gas (IIB) → Ex d IIB T4
  • Hydrogen / acetylene (IIC) → must be Ex d IIC T6 or Ex ia IIC T6

3. Certification documents are mandatory

  • China: Ex certificate (CNEX etc.) + factory calibration report
  • Export to Middle East / Central Asia: ATEX / IECEx; Saudi Arabia also requires SABER/SASO
  • Sour service: material certificate + NACE MR0175 optional

4. Wetted material must match the medium

  • Water / air: 304 stainless steel
  • Oil & gas / seawater / chlorides: 316L
  • H₂S / CO₂: 316L + diaphragm seal, or Hastelloy
  • High-temperature steam: siphon / cooling tube
  • Viscous / crystallizing: diaphragm seal + flushing ring

5. Accuracy and dial size

  • General industry: 1.6 class (piping, pumps, tank farms)
  • Metering / control: 1.0 class or better
  • Dial size: φ63/φ100 in cabinets, φ150 for long-distance inspection

Part 2 — How to Select the Pressure Range (Headroom Is Critical)

1. Golden rules

  • Steady pressure: working pressure within 1/3 to 2/3​ of the range
  • Pulsating pressure: peak × 1.5 to 2 times​ (2–3 times for severe pulsation)
  • Do not exceed 2/3 of the range in continuous operation

2. Quick examples

  • Normal 0.6 MPa → choose 0–1.0 / 0–1.6 MPa
  • Pump discharge 20 MPa pulsating, peak 28 → choose 0–40 MPa liquid-filled gauge
  • Wellhead peak 80 MPa → choose 0–100 / 0–160 MPa
  • Vacuum + pressure: choose -0.1 to 0.5 MPa compound gauge

3. Range vs. application

 
Range
Typical application
0–0.1 / 0–0.6 MPa
Gas regulation, fans, HVAC, tank farm micro-pressure
0–1.6 / 0–2.5 MPa
Separators, low-pressure networks, boiler feed water
0–4 / 0–6 MPa
Gas regulating stations, gas injection, fire pumps
0–10 / 0–16 MPa
Chemical reactors, medium-pressure manifolds
0–25 / 0–40 MPa
Water injection pumps, compressor discharge, mid-stage wellhead
0–60 / 0–100 MPa
Oil & gas wellheads, high-pressure manifolds, fracturing
Above 0–160 MPa
Ultra-high-pressure wells, hydraulic systems, special duties

Part 3 — Five Real Installation Cases

Case 1 — Oil wellhead (Zone 1, H₂S present)

  • Configuration: Ex d IIC T6 flameproof liquid-filled gauge, 0–100 MPa, φ150, 316L, glycerin filled
  • Accessories: needle valve + siphon + diaphragm seal
  • Installation: dial vertical upward, open root valve slowly; overpressure signal to ESD shutdown
  • Key points: sour service, vibration resistance, surge protection

Case 2 — Oil-gas separator (Zone 1, two-phase flow with particles)

  • Configuration: Ex d IIB T4, 0–2.5 MPa (normal 0.8–1.6 MPa)
  • Accessories: 316L diaphragm flange + drain valve
  • Installation: tap on the side center of the vessel, away from gas/liquid pockets
  • Key points: diaphragm prevents clogging; drain residue regularly

Case 3 — Water injection pump discharge (Zone 2, strong pulsation)

  • Configuration: Ex d IIB T4 silicone-filled gauge, 0–40 MPa
  • Accessories: pulsation damper + buffer bend
  • Installation: wrench on the hex of the fitting only, never on the case
  • Key points: without a damper, the movement fails within 3 months

Case 4 — Natural gas compressor (Zone 1, IIC)

  • Suction: Ex ia IIC T4 intrinsically safe gauge (with barrier)
  • Discharge: Ex d IIC T6, 0–60 bar
  • Installation: IS loop wired separately, explosion-proof flexible conduit + gland
  • Key points: overpressure trips the compressor; low pressure prevents surge

Case 5 — Crude oil tank roof (Zone 1, IIB T4)

  • Duty: micro-pressure fluctuation -0.1 to 0.18 MPa, with nitrogen blanketing
  • Configuration: explosion-proof contact gauge, -0.1 to 0.2 MPa, φ100, 316L, IP65 liquid filled
  • Installation: radial front flange mounting, dual contacts (high opens breather valve / low starts nitrogen)
  • Key points: blow-out cover facing outward; all cable entries sealed with plugs

Part 4 — Installation Red Lines (for agents and site teams)

  1. In a hazardous area, a mechanical gauge is not an electrical Ex gauge; anything with power needs an Ex certificate
  2. Flameproof gauge: all bolts tight, glands sealed, unused entries plugged
  3. Intrinsically safe gauge: barrier + separate wiring + single-point grounding
  4. High temperature → siphon; pulsation → damper; corrosion → diaphragm seal
  5. Wrench on the fitting, never on the dial head; never rotate a diaphragm seal body
  6. Outdoor IP65 minimum; add sand and salt-spray protection for desert and offshore

Part 5 — What DERKIA Offers Agents

  • Full oil & gas explosion-proof range: flameproof / intrinsically safe, liquid-filled, diaphragm sealed
  • Ranges from 0 to 160 MPa, covering wellhead to tank farm
  • 316L, Arabic / English / Russian dials, calibration report with every batch